info@melbourneug.com.au

[vc_row css_animation=”” row_type=”row” use_row_as_full_screen_section=”no” type=”full_width” angled_section=”no” text_align=”left” background_image_as_pattern=”without_pattern”][vc_column][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”90px 15px 60px 15px” vertical_alignment=”middle” horizontal_alignment=”center” advanced_animations=”no” custom_class=”title-container”][vc_column_text]

Projects

[/vc_column_text][/qode_elements_holder_item][/qode_elements_holder][vc_row_inner row_type=”row” type=”grid” text_align=”left” css_animation=””][vc_column_inner el_class=”vc_col-sm-push-6″ width=”1/2″ offset=”vc_col-md-6″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 90px 15px” advanced_animations=”no” item_padding_480=”0px 15px 30px 15px”][vc_column_text]

PLENTY RD HV/LV POWER UPGRADE STAGE 2

 

Location: South Morang/Mernda

Client: Lend Lease

Start date: May 2020

Completion date: April 2021[/vc_column_text][vc_empty_space][vc_column_text]JLM relocated the HV and LV power services underground, over a 6km stretch of Plenty Road through South Morang and Mernda. JLM’s package included boring and trenching for installation of new conduits, cable hauling (both HV and LV), installation pits and switching stations, and auditing and detailing. JLM utilised non-destructive digging (NDD) methods to safely excavate through cultural heritage sites in the area.[/vc_column_text][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][vc_column_inner el_class=”vc_col-sm-pull-6″ width=”1/2″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 90px 15px” advanced_animations=”no” item_padding_480=”0px 15px 60px 15px”][vc_single_image image=”694″ img_size=”full” alignment=”center” qode_css_animation=””][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css_animation=”” row_type=”row” use_row_as_full_screen_section=”no” type=”full_width” angled_section=”no” text_align=”left” background_image_as_pattern=”without_pattern” css=”.vc_custom_1619138343170{background-color: #f6f6f6 !important;}” z_index=””][vc_column][vc_row_inner row_type=”row” type=”grid” text_align=”left” css_animation=”” css=”.vc_custom_1619138351625{background-color: #f6f6f6 !important;}”][vc_column_inner el_class=”vc_col-sm-push-6″ width=”1/2″ offset=”vc_col-md-6″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 90px 15px” advanced_animations=”no” item_padding_480=”0px 15px 30px 15px”][vc_column_text]

O’Herns Rd Power Upgrade

 

Location: Epping

Client: Lend Lease

Start date: October 2019

Completion date: March 2020[/vc_column_text][vc_empty_space][vc_column_text]JLM directionally drilled and trenched to relocate HV and LV power services underground, over a 1km stretch of O’Herns Road in Epping. JLM’s package included boring and trenching, installing conduits, cable hauling, pipe welding, NDD excavation, pit installation, and auditing and detailing.

JLM used both D40x55DR rock drills to bore through extremely hard bluestone rock encountered throughout this area. One conduit installation involved a 200m bore under the Hume Fwy reamed to 380mm. JLM utilised the mud recycler to increase efficiency and reduce waste produced.[/vc_column_text][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][vc_column_inner el_class=”vc_col-sm-pull-6″ width=”1/2″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 90px 15px” advanced_animations=”no” item_padding_480=”0px 15px 60px 15px”][vc_single_image image=”695″ img_size=”full” alignment=”center” qode_css_animation=””][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css_animation=”” row_type=”row” use_row_as_full_screen_section=”no” type=”full_width” angled_section=”no” text_align=”left” background_image_as_pattern=”without_pattern” z_index=””][vc_column][vc_row_inner row_type=”row” type=”grid” text_align=”left” css_animation=””][vc_column_inner el_class=”vc_col-sm-push-6″ width=”1/2″ offset=”vc_col-md-6″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 90px 15px” advanced_animations=”no” item_padding_480=”0px 15px 30px 15px”][vc_column_text]

Yan Yean Rd Duplication

Location: Plenty

Client: Lend Lease

Start date: July 2018

Completion date: In progress[/vc_column_text][vc_empty_space][vc_column_text]JLM are directionally drilling and open cut trenching to relocate HV and LV power services underground, over a 4km stretch of Yan Yean Rd in Melbourne’s northeast.

While working in with live traffic on this busy arterial road, JLM are using our D40x55DR rock drill, our D36x50ii and our D24x40ii to bore through the hard mudstone encountered throughout this area. JLM’s package involves boring and trenching, installing conduits, installing pits, and auditing and detailing. The bores under the existing road have up to 5 conduits per run, with a 500mm bore annulus.[/vc_column_text][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][vc_column_inner el_class=”vc_col-sm-pull-6″ width=”1/2″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 90px 15px” advanced_animations=”no” item_padding_480=”0px 15px 60px 15px”][vc_single_image image=”616″ img_size=”full” alignment=”center” qode_css_animation=””][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css_animation=”” row_type=”row” use_row_as_full_screen_section=”no” type=”full_width” angled_section=”no” text_align=”left” background_image_as_pattern=”without_pattern” css=”.vc_custom_1619138522634{background-color: #f6f6f6 !important;}” z_index=””][vc_column][vc_row_inner row_type=”row” type=”grid” text_align=”left” css_animation=””][vc_column_inner el_class=”vc_col-sm-push-6″ width=”1/2″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 60px 15px” advanced_animations=”no” item_padding_480=”60px 15px 30px 15px”][vc_column_text]

Select Harvest HV Links

Location: Robinvale

Client: Trivantage

Start date: January 2015

Completion date: January 2015[/vc_column_text][vc_empty_space][vc_column_text]JLM directionally bored and chain trenched 4.1km of 125mm HD electrical conduit to upgrade a low voltage metred feed to a high voltage metred feed, in order for the client to be metred directly from the power supplier (Powercor).

The majority of this 4.1km stretch was through almond farms, where JLM had to take the utmost care with environmental management. JLM had to follow a strict environmental management plan, ensuring all environmental controls were effectively installed each day, and all machinery was washed thoroughly before entering and exiting site to avoid the spread of weeds and foreign contaminants.[/vc_column_text][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][vc_column_inner el_class=”vc_col-sm-pull-6″ width=”1/2″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 60px 15px” advanced_animations=”no” item_padding_480=”0px 15px 60px 15px”][vc_single_image image=”618″ img_size=”full” alignment=”center” qode_css_animation=””][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css_animation=”” row_type=”row” use_row_as_full_screen_section=”no” type=”full_width” angled_section=”no” text_align=”left” background_image_as_pattern=”without_pattern” z_index=””][vc_column][vc_row_inner row_type=”row” type=”grid” text_align=”left” css_animation=””][vc_column_inner width=”1/2″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 90px 15px” advanced_animations=”no” item_padding_480=”60px 15px 30px 15px”][vc_column_text]

Melbourne Airport HV Upgrade

Location: Tullamarine

Client: Avionics

Start date: June 2013

Completion date: April 2014[/vc_column_text][vc_empty_space][vc_column_text]At the Melbourne Airport HV upgrade, JLM directionally drilled under live runways and taxiways. JLM drilled a 180m 6 x 125mm HV 600mm annulus pressure grouted drill shot 8m deep under Runway 16/34 and a 140m 4 x 125mm HV 450mm annulus pressure grouted drill shot 8m deep under Runway 09/27. JLM installed tremie lines for the pressure grouting to backfill the annulus.

In order to not impede air traffic using the runways, JLM drilled a sacrificial pump line under the runway to direct the waste fluid back to our drill fluid recycling system during every bore to reduce waste creation. This detailed setup allowed for maximum efficiency and minimum disruptions during our compressed time frame.[/vc_column_text][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][vc_column_inner width=”1/2″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 90px 15px” advanced_animations=”no” item_padding_480=”0px 15px 60px 15px”][vc_single_image image=”619″ img_size=”full” alignment=”center” qode_css_animation=””][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row css_animation=”” row_type=”row” use_row_as_full_screen_section=”no” type=”full_width” angled_section=”no” text_align=”left” background_image_as_pattern=”without_pattern” css=”.vc_custom_1619138539122{background-color: #f6f6f6 !important;}” z_index=””][vc_column][vc_row_inner row_type=”row” type=”grid” text_align=”left” css_animation=””][vc_column_inner el_class=”vc_col-sm-push-6″ width=”1/2″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 60px 15px” advanced_animations=”no” item_padding_480=”60px 15px 30px 15px”][vc_column_text]

Plenty Rd HV/LV Power Upgrade

Project: Plenty Road Upgrade

Location: Bundoora/Mill Park

Client: Lend Lease

Start date: October 2018

Completion date: April 2019[/vc_column_text][vc_empty_space][vc_column_text]JLM directionally drilled and open cut trenched to relocate HV and LV power services underground, over a 2km stretch of Plenty Road through Bundoora and Mill Park. JLM’s package included boring and trenching, installing conduits, NDD excavation, installing pits and cable switching stations, and auditing and detailing. This project was undertaken while maintaining live traffic on Plenty Road.

JLM used the D40x55DR rock drills to bore through extremely hard basalt rock encountered throughout this area up to 500mm diameter. The specialised rock drills allowed JLM to drill with such efficiency that the original dates were met despite the strength of the rock encountered. This allowed Lend Lease and Decmil to meet their HV shutdown dates, and deliver their project on time.[/vc_column_text][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][vc_column_inner el_class=”vc_col-sm-pull-6″ width=”1/2″][qode_elements_holder number_of_columns=”one_column”][qode_elements_holder_item item_padding=”60px 15px 60px 15px” advanced_animations=”no” item_padding_480=”0px 15px 60px 15px”][vc_single_image image=”685″ img_size=”full” alignment=”center” qode_css_animation=””][/qode_elements_holder_item][/qode_elements_holder][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row]